Natural Composite FLOATING FLOORING
INSTALLATION & CARE INSTRUCTIONS
ENGINEERED SWISS PERFORMANCE
OVERVIEW
Natural Composite Flooring uses a click-lock interlocking system. Panels connect without adhesive. Prepare chipboard or timber subfloors so they are level and vibration-free before installation. Follow the product-specific installation guide.
Note: Only floors with a Hydrowood core are approved for use in moisture-prone areas like bathrooms and may be glued directly to the subfloor. HDF-core floors should not be glued. For wet-area installations, a post-installation sealing with Loba 2K Supra AT is recommended.
SUBFLOOR REQUIREMENTS
The base surface must be clean, level, dry, and stable per DIN 18365 standards.
-
Floor irregularities must not exceed 3mm over 1 meter.
-
Do not install over carpet or soft floor coverings.
Permissible Moisture (CM Method):
-
Cement screeds: < 2.0% (or < 1.8% for heated screeds)
-
Anhydrite screeds: < 0.5% (or < 0.3% if heated)
CONDITIONING THE FLOORING
-
Keep unopened boxes flat in the room for at least 24 hours before installation.
-
Room conditions: 15–25°C (59°–77°F) and 40–60% relative humidity.
PRE-INSTALLATION INSPECTION
-
Check each plank in daylight for visible damage or flaws.
-
Minor imperfections can be used where cuts are needed.
-
Do not proceed if materials or site conditions are unsuitable.
VAPOR BARRIER (PE FILM)
-
Lay 0.2mm PE sheet over all mineral-based subfloors.
-
Overlap seams by 20cm and seal with tape.
-
Extend barrier 2–3cm up walls to ensure moisture control.
Tip: PE foil helps your floating floor “float” properly across most subfloors.
BUILT-IN SOUND CONTROL
All Natural Composite floating floors are equipped with a pre-attached cork or Green Sound underlay. No extra sound insulation is necessary.
Optional: If adding underlayment, ensure it has a compression strength of ≥200 kPa.
EXPANSION ALLOWANCE
-
Maximum continuous installation area: 30m x 24m (approx. 100ft x 80ft).
-
Maintain a 10mm expansion gap around all walls, fixed objects, and structural features.
-
Do not fill perimeter joints with sealant—use appropriate edging profiles.
FITTING INSTRUCTIONS
-
Mix planks from several boxes to blend natural variations.
-
Lay planks parallel to the primary light source in the room.
Two click-lock methods:
Method 1: Angle-to-Angle
-
Tilt the plank (~10°), fit the tongue into the groove, and press down to lock.
-
Use a 20cm tapping block and mallet for snug seams.
Method 2: Angle & Tap
-
Join short ends first by tapping.
-
Then tilt and click the lengthwise edge into place.
Offset joints by at least 20cm (ideal: 40cm) for strength and aesthetic flow.
ADDITIONAL GUIDANCE
-
Never glue, screw, or nail floating planks.
-
For heavy furniture (e.g., stone-top islands, wood stoves), either install before the flooring or create expansion breaks around them.
-
For bathroom use, glue down Hydrowood core planks and seal all joints with silicone and PE backing rods.
INSTALLING AROUND FIXTURES
-
Maintain 10mm clearance around pipe penetrations, columns, and frames.
-
Cut planks precisely and reattach sections with adhesive tape.
-
Never drill or screw door stops directly through the floor.
UNDERFLOOR HEATING COMPATIBILITY
-
Maximum floor surface temperature: 28°C (82°F).
-
Heating systems must be fully embedded in leveling compound (minimum 2mm).
-
Apply glue at click connections for added joint stability.
Tip: Follow heating system manufacturer’s heat-up and cooldown protocols.
CLEANING & MAINTENANCE
-
Sweep, vacuum, or lightly damp mop after installation.
-
Use a PU cleaner for heavy dirt or grease.
-
Avoid harsh chemicals and abrasive pads.
Initial Protection: Apply a thin protective finish post-installation to extend floor life.
Floor Care Tips:
-
Use non-staining entrance mats (e.g., nitrite rubber).
-
Avoid rubber-based mats or furniture pads.
-
Choose soft caster wheels (EN 12529 Type W) for furniture.
For more installation videos, product specifications, or expert advice, please contact your authorized Natural Composite dealer or visit our website.