The Condo & Strata Acoustic Approval Kit
Everything your strata council wants to see before it approves your new floor — in one download.
If you own a condo in Canada, you already know the drill: before you can replace your flooring, your strata council wants proof that the new floor won’t send footstep noise into the unit below. Most flooring stores answer with a marketing brochure. We answer with test reports.
Cork is the original acoustic floor, and we’ve been testing ours for decades — impact sound reduction to ISO 717-2 and ISO 140-8, Delta IIC assemblies to ASTM E2179, and full STC/IIC ratings for every cork underlayment we sell, on a standard 6-inch concrete slab, with and without a suspended ceiling. No inflated lab fantasy numbers. Just documents your strata can actually read.
Download the Kit (ZIP)
What your strata is actually asking for
Most strata bylaws reference one of three numbers. They are not interchangeable, and understanding the difference is the fastest way to get approved:
IIC (Impact Insulation Class) rates how well a floor-ceiling assembly blocks impact sound — footsteps, dropped objects, chair legs. It is measured on the whole structure: slab, ceiling, insulation, and floor covering combined. A bare 6-inch concrete slab typically tests around IIC 27 on its own.
STC (Sound Transmission Class) is the same idea for airborne sound — voices, TV, music. Strata councils sometimes quote STC minimums alongside IIC.
ΔIIC (Delta IIC, ASTM E2179) measures only the improvement the flooring and underlay contribute, with the slab’s contribution mathematically removed. It is the one number that travels from building to building, and the only fair way to compare two products. As a rule of thumb: ΔIIC 14 is a good acoustic floor; ΔIIC 20 is excellent. Thin foam underlays typically contribute single digits to low teens.
ΔLw (EN ISO 717-2) is the European equivalent — impact sound reduction in decibels. Our European-made lines (Swiss Design cork, TechSlate) are rated this way: 18–19 dB.
When a bylaw says “IIC 50” or “IIC 72,” it is talking about the finished assembly in your unit — which is why the kit includes both the per-product test statements and a cover letter that shows the assembly math.
Tested sound ratings for our floors and underlayments
Every figure below is taken from a hosted test document. The source file for each row is linked — the same files that are inside the kit.
Tested combinations: 12mm cork floating floor over cork underlayment
| Combination |
Total tested sound reduction |
Source document |
| 12mm floating floor + 3mm cork underlayment |
31 dB |
Test sheet (JPG) |
| 12mm floating floor + 6mm cork underlayment |
42 dB |
Test sheet (JPG) |
| 12mm floating floor + 12mm cork underlayment |
67 dB |
Test sheet (JPG) |
Recommended strata-friendly combinations
Best acoustic result — “the strata special.” 12mm cork floating flooring over 12mm cork underlayment. Tested at 67 dB total sound reduction; the underlayment alone carries IIC 75 / STC 76 on 6-inch concrete. For wood-frame buildings and the strictest councils.
Best value — the tested assembly. Any 11–12mm cork floating floor over 6mm cork underlayment. This is the exact combination tested to ΔIIC +20 (ASTM E2179) — the number to lead with in the cover letter, because it is building-independent. The 12mm floating version of this pairing tests at 42 dB total reduction.
Slim profile / over radiant heat. Swiss Design 11mm cork floating — 18 dB (EN ISO 717-2), no separate underlayment required thanks to its attached cork underlay layer. Where ceiling height or hydronic heat rules out thick assemblies.
Glue-down route (where strata requires bonded floors). 6mm glue-down cork tile at 18 dB impact sound reduction.
Design-led. Swiss TechSlate 7.5mm — stone visuals at approx. 19 dB (EN ISO 717-2), for owners who need approval and a non-cork look.
Download the kit
One zip file with everything your strata council needs:
- 12mm / 6mm / 3mm cork underlayment acoustic test statements (PDF)
- 12mm cork floating floor IIC test report (PDF)
- ΔIIC +20 assembly test summary (JPG)
- Strata cover-letter template (HTML + Markdown) — fill in your unit, building, and chosen products
- Indoor-air-quality certificates: GreenGuard Gold, ECO Institut, CE (PDF)
Download the Kit (ZIP) Cover Letter Only (PDF) Cover Letter Only (Markdown)
Common strata questions
My strata just says “IIC 50 minimum.” What does that mean for me?
It means the whole floor/ceiling assembly — slab, ceiling, and your floor together — must reach IIC 50. Ask your strata or property manager what the building already tests at. A 6-inch concrete slab on its own is typically around IIC 27; our tested cork systems add the rest. The cover letter in the kit walks your council through the math.
I live in a wood-frame building. Does this still apply?
Yes — and wood frames need the most help, because a wood-joist structure transmits far more impact sound than a concrete slab. A floating cork floor over cork underlayment is the combination most often approved in wood-frame strata buildings; lead with the ΔIIC +20 assembly result and the per-product test statements in the kit.
Do I have to use cork flooring, or just cork underlayment?
Cork underlayment works under most floating floors, and many owners use it exactly that way. Pairing it with a cork floating floor adds a second acoustic layer and the highest tested results.
My strata wants proof of indoor air quality too. Is that in the kit?
Yes. The kit includes our GreenGuard Gold, ECO Institut, and CE certificates, and the cover letter references them directly.
Keep reading